Hi,
there seems to typo in _qiv completion :
- '(-c --contrast)'{-b,--contrast}'[set contrast]:contrast (-32..32)' \
and
- '(-g --gamma)'{-b,--gamma}'[set gamma]:gamma (-32..32)' \
from my manual
-c and -g are the rights options for contrast and gamma respectively.
I join a correction suggestion
arno.
--- _qiv 2006-11-24 05:37:22.000000000 +0100
+++ _qiv~ 2007-01-02 19:19:15.000000000 +0100
@@ -14,8 +14,8 @@
'(-m --maxpect)'{-m,--maxpect}'[expand image to fit screen size]' \
'(-t --scale_down)'{-t,--scale_down}'[shrink images to fit screen size]' \
'(-b --brightness)'{-b,--brightness}'[set brightness]:brightness (-32..32)' \
- '(-c --contrast)'{-b,--contrast}'[set contrast]:contrast (-32..32)' \
- '(-g --gamma)'{-b,--gamma}'[set gamma]:gamma (-32..32)' \
+ '(-c --contrast)'{-c,--contrast}'[set contrast]:contrast (-32..32)' \
+ '(-g --gamma)'{-g,--gamma}'[set gamma]:gamma (-32..32)' \
'(-n --no_filter)'{-n,--no_filter}'[disable filtering of images by extension]' \
'(-i --no_statusbar -I --statusbar)'{-i,--no_statusbar}'[disable statusbar]' \
'(-i --no_statusbar -I --statusbar)'{-I,--statusbar}'[enable statusbar]' \
Attachment:
signature.asc
Description: Digital signature